Monitoring Particle Counter CLIMET – Trident CI-3100-SRS
Features
. Flow Rate Control: Critical orifice @ 1.0 cfm
. External Vacuum: 15’’ Hg minimum
. Particle Channel Sizes: 2 channels 0.5/5 µm
. Laser Diode: Optimal balance of long life, stability, and resolution for added accuracy
. Cleaning: Compatible with common cleaning and sterilization procedures, including VHP
. RH/Temp output: Compatible with RH/Temp probe
. Alarms: Front Panel LEDs, Light Ring, and output for the Climet Trident Light
. Leds Status Indicators: Power, Sample, Alarm, Count, Laser Status, Flow Status, Network FTP, Network Time, Service required and Network Link
. Environmental:
– Operating temperature: 0-37.8°C, 32-100°F,
– Dimensions: 16.26 x 10.6 x 14.99 cm,
– 0-95% relative humidity, non-condensing
. Compliance: ISO 21501-4; ISO 14644-1; EU GMP, Annex 1; and FDA 21 CFR Part 11
Accessories included: manuel, USB cable, mounting bracket and quick start guide.
The Trident RS particle counter is a 2-channel particle counter used in continuous monitoring applications in a variety of industries – generally Grade A or B (ISO 5) biopharmaceutical or medical device clean zones. The standard particle sizes are 0.5 µm and 5.0 µm. Designed for fixed continuous monitoring applications with an external vacuum pump, the CI-3100 Trident RS offers a standard flow rate of 1 CFM.
The Trident RS Series is provided with your choice of Power-over-Ethernet (POE) or 24 VDC power. The CI-3100 Trident RS is compatible with either POE or POE+. This technology injects power and ground onto standard network cabling, thus eliminating the need for wall power. POE is a much sought after technology given safety protocols of some of the larger pharmaceutical and biotechnology producers. Sample data is provided end-users with a choice of either Ethernet Modbus, or Push to FTP CSV file upload; and the Trident model connects to existing network infrastructure. The sample data output is 21 CFR Part 11 compliant, and can be easily uploaded into standard environmental monitoring systems including LIMS software.
Accessories
. Stainless steel isokinetic probes
. Tubing
. Probe stands
. High pressure diffusers
. Software
Associated services
Customised IQ/OQ protocols developed according to your application.
Training session on site or in our office related to regulation, equipment use and data treatment .
Calibration and metrological services are performed in our laboratory located at Betton (35).