Indoor Air Quality Meter TSI Model 7545

Indoor Air Quality Meter TSI Model 7545

. CO2, temperature, humidity.
. Dew point, wet bulb temperature.
. Percentage outside air.
. Detection of carbon monoxide (CO).

SKU: ff75c44767b8 Categories: ,

Need information

Share Product

Click here

Features

CO2:
Sensor Type: Dual-wavelength NDIR
(non-dispersive infrared)
Range Accuracy
1: 0 to 5,000 ppm
±3.0% of reading or ±50 ppm, whichever is greater
Resolution Response: 1 ppm
Time: 20 seconds

CO:
Sensor Type: Electro-chemical
Range: 0 to 500 ppm
Accuracy: +3% of reading or +3ppm
Whichever is greater
Resolution: 0.1 ppm
Response time: <60 seconds to 90% step change

Temperature:
Sensor Type: Thermistor
Range: 0 to 60°C (32 to 140°F)
Accuracy: ±0.5°C (±1.0°F)
Resolution: 0.1°C (0.1°F)
Response Time: 30 seconds (90% of final value, air velocity at 2 m/s [400 ft/min])

Relative Humidity:
Sensor Type: Thin-film capacitive
Range: 5% to 95% RH
Accuracy
2: ±3.0% RH
Resolution: 0.1% RH
Response Time: 20 seconds (for 63% of final value)

Percentage Outside Air:
Range: 0 to 100%
Resolution: 0.1%

Operating Temperature:
5 to 45°C (40 to 113°F)

Storage Temperature:
-20 to 60°C (-4 to 140°F)

Logging Capability:
Range: Model 7545 logs up to 26,900 data points with key (4) measured parameters enabled
Time Constant: 1 sec, 5 sec, 10 sec, 20 sec, 30 sec (user selectable)
Log Intervals: 1 second up to 1 hour (user selectable)

Meter Dimensions:
8.4 cm x 17.8 cm x 4.4 cm
(3.3 in. x 7.0 in. x 1.8 in.)

Probe Dimensions:
Length 17.8 cm (7.0 in.)
Diameter 1.9 cm (0.75 in.)

1 Accuracy with probe at 25°C (77°F). Add uncertainty of ±0.36%/°C (±0.2%/°F) away from calibrated temperature.
2 Accuracy with probe at 25°C (77°F). Add uncertainty of ±0.2% RH/°C (±0.1% RH/°F) away from calibrated temperature. 

Associated services

. First level maintenance and repair work performed by Aerometrik.

. Taking charge of and monitoring the metrology of this equipment with TSI.

You may also like…

  • Micromanometer DP-CALC TSI Model 5825

    . Measure differential and static pressure from -15 to 15 in.
    . H2O (-3735 to +3735 Pa).
    . Calculate and display velocity when using a Pitot tube.
    . Calculates flow, variable time constant, statistics, data logging with time and date stamp, stores 12,700+ samples and 100 test IDs.
    . Progammable K factors.

  • Air Velocity Meters VELOCICALC TSI Model 9515

    . The Model 9515 is an economical choice for a digital air velocity meter, without compromising accuracy or precision.
    . Professionals find them to be the ideal tool for face velocity measurements in fume hoods, spray booths, or ventilation system checks.

  • Indoor Air Quality Meter TSI Model 7515

    . Low-drift NDIR CO2 sensor for stable, accurate readings.
    . Sampling function records multiple point measurements.
    . Ergonomic, overmolded case design.

    Download the product sheet