Accubalance Air Capture Hood TSI Model 8380
. Accurately measures pressure, velocity and flow to help you meet industry standards
. Auto-zeroingpressure sensor reduces user-steps and saves time
. Automatic density correction increases reading accuracy
. Intuitive menu structure allows for ease of use and setup
. Large graphic display with backlight offers easy-to-use interface
– Displays up to five measurements simultaneously
– On-screen messages and instructions
– Programmed for multiple languages
. Integrated Log-Tchebycheff duct traverse application simplifies calculations
. Bluetooth communications for transferring data or remote polling
. Includes downloading software with USB cable
. Accommodates optional pitot, air flow (straight pitot),
temperature/relative humidity, velocity matrix, or thermoanemometer probes for use in multiple applications
Features
Specifications
Models 8715 and 8380
Velocity Range
. Pitot probes: 25 to 15,500 ft/min (0.125 to 78 m/s)
. Air flow probe: 25 to 5,000 ft/min (0.125 to 25 m/s)
. Velocity matrix: 25 to 2,500 ft/min (0.125 to 12.5 m/s)
. Accuracy: ±3% of reading ±7 ft/min (±0.04 m/s) at velocities >50 ft/min (>0.25 m/s)
. Units Resolution: ft/min, m/s
Pressure
. Differential pressure: ±15 in. H2O (±3735 Pa);
150 in. H2O (37.5 kPa),
maximum safe operating pressure
. Absolute pressure: 15to40in.Hg(356to1016mmHg)
. Accuracy: ±2% of reading ±0.0001 in. H2O (±0.025 Pa) static and differential; ±2% of reading absolute
. Units: in. H2O, in. Hg, Pa, hPa, kPa, mm Hg,
cm Hg, mm H2O, cm H2O
. Resolution: 0.00001 in. H2O (0.001 Pa) static and differential; 0.01 in. Hg (1 mm Hg) absolute
Volume
. Range: 25 to 2,500 ft3/min (42 to 4250 m3/h) capture hood
. Accuracy: ±3% of reading ±7 ft3/min (±12 m3/h) at
flows >50 ft3/min (>85 m3/h)
. Units: ft3/min, m3/h, m3/min, l/s
. Resolution: 1 ft3/min (1 m3/h)
RH
. Range: 5 to 95% RH temperature/RH probe
. Accuracy: ±3% RH
. Resolution: 0.1% RH
Temperature
. Sensor in base: 40 to 140°F (4.4 to 60°C)
. Temperature/RH probe: 14 to 140°F (-10 to 60°C)
. Accuracy: ±0.5°F (±0.3°C)
. Units: °F, °C
. Resolution: 0.1°F (0.1°C)
Instrument Temperature Range
. Operating: 40 to 140°F (4.4 to 60°C)
. Storage: -4 to 160°F (-20 to 71°C)
Statistics
. Min, max, average
Data Storage
. 26500 samples, time and date stamped
Logging Interval
. User selectable
Response Time:
. 2 to 8 seconds, differential pressure sensor
Dimensions (manometer only)
. 7.4 in. x 4.5 in. x 2.3 in. (18.8 cm x 11.4 cm x 5.8 cm)
Pressure Connection
. 1/4 in. (6.35 mm) OD straight ports with barbed ends for use with 3/16 in. (4.76 mm) ID flexible tubing
Weight with Batteries
. 8715 17 oz (0.5 kg)
. 8380 7.4 lb (3.4 kg)
Power Requirements
Four AA-size cells or AC adapter
Accessories
Included Items:
. 2 ft. x 2 ft. (610 mm x 610 mm) air capture hood/frame/base
. Detachable micromanometer
. Swirl X Flow Conditioner
. (4) AA size rechargeable NiMH batteries
. Multi-country AC adapter
. 18 in. (46 cm) Pitot probe
. (2) Static Pressure probes
. 16 ft (4.8 m) Neoprene tubing
. Wheeled luggage-style carrying case
. NIST traceable calibration certification
. Downloading software
. USB interface cable
. Manual
Hood Sizes Available (8380) Standard Hood Kits
801180: 2ftx2ft(610mmx610mm)
Optional Hood Kits
2ftx4ft(610mmx1220mm)
1ftx4ft(305mmx1220mm)
1ftx5ft(305mmx1525mm)
3ftx3ft(915mmx915mm)
16in.x16in.(406mmx406mm)
5.25in.x4ft(133mmx1220mm)
28in.x28in.(710mmx710mm)
28in.x50in.(710mmx1270mm)
BSC Hood Kit
8in.x22in.(205mmx560mm)
10in.x22in.(255mmx560mm)
Recommended Accessories
800187 Air flow probe (straight pitot), 18 in. (46 cm)
800218 Temperature probe
800219 Humidity and temperature probe
801090 Velocity matrix, telescopic handle, (2) 8 ft. (2.4 m) neoprene tubing sections
960 Air Velocity and Temperature, Straight Probe
962 Air Velocity and Temperature, Articulating Probe
964 Air Velocity, Temperature, and Humidity, Straight Probe
966 Air Velocity, Temperature, and Humidity, Articulating Probe
634634000 Pitot probe 5/16 in. (8 mm) diameter – 12 in. (30 cm)
634634001 Pitot probe 5/16 in. (8 mm) diameter – 18 in. (46 cm)
634634002 Pitot probe 5/16 in. (8 mm) diameter – 24 in. (61 cm)
634634003 Pitot probe 5/16 in. (8 mm) diameter – 36 in. (91 cm)
634634005 Pitot probe 5/16 in. (8 mm) diameter – 60 in. (152 cm)
634650002 Duct plug, 3/8 in. (9.5 mm) diameter – 1000 pieces
634650003 Duct plug, 3/8 in. (9.5 mm) diameter – 5000 pieces
8934 Wireless Bluetooth Printer
Associated services
. First level maintenance and repair work performed by Aerometrik.
. Taking charge of and monitoring the metrology of this equipment with TSI.
You may also like…
-
Micromanometer DP-CALC TSI Model 5825
. Measure differential and static pressure from -15 to 15 in.
. H2O (-3735 to +3735 Pa).
. Calculate and display velocity when using a Pitot tube.
. Calculates flow, variable time constant, statistics, data logging with time and date stamp, stores 12,700+ samples and 100 test IDs.
. Progammable K factors. -
Micromanometer DP-CALC TSI Model 5815
. Measure differential and static pressure from -15 to 15 in.
.H2O (-3735 to +3735 Pa).
. Calculate and display velocity when using a Pitot tube. -
Air Velocity Meters VELOCICALC TSI Model 9515
. The Model 9515 is an economical choice for a digital air velocity meter, without compromising accuracy or precision.
. Professionals find them to be the ideal tool for face velocity measurements in fume hoods, spray booths, or ventilation system checks.