VelociCalc Multi-Function Ventilation Meter TSI 9565
. Straight Air Velocity Probe 964 measure air velocity, temperature and relative humidity
. Includes differential pressure sensor
. Best-in-class air velocity accuracy
. Optional “smart” plug-in probes, including VOC, CO2, and rotating vane probes
. Accommodates up to two K-alloy thermocouples
. Large graphic display
. Displays up to five measurements simultaneously
. On-screen messages and instructions
. Program for local language
. Intuitive menu structure allows for ease of use and setup
. Multiple data logging formats
. Bluetooth communications for transferring data or remote polling
. Includes TrakPro™ and LogDat2™ downloading software with USB cable
Features
To Order
Multi-Function Ventilation Meter with differential pressure sensor and Thermoanemometer Probe
Specify Description
. 9565 Multi-function ventilation meter 9565-P with straight air velocity probe Model 964
. 9565-NB Multi-function ventilation meter 9565-P-NB (no Bluetooth®) with straight air velocity probe Model 964
. 9565-A Multi-function ventilation meter 9565-P with
articulated air velocity probe Model 966 9565-A-NB Multi-function ventilation meter 9565-P-NB (no Bluetooth®) with articulated air velocity probe Model 966
Multi-Function Ventilation Meter only. Choose a probe most appropriate for your measurement needs.
Specify Description
. 9565-X: Multi-function ventilation meter, no plug-in probes, no differential pressure sensor
. 9565-X-NB: Multi-function ventilation meter, no plug-in probes, no differential pressure sensor, no Bluetooth®
. 9565-P: Multi-function ventilation meter, no plug-in probes, with differential pressure sensor tubing and static pressure probe
. 9565-P-NB: Multi-function ventilation meter, no plug-in probes,with differential pressure sensor, no Bluetooth
All models include: Instrument, hard carrying case, 4 alkaline batteries,
USB cable, universal power supply, instruction manual, calibration certificate, LogDat2TM and TrakProTM downloading software.
Specifications:
Velocity (Pitot or Airflow probe for Models 9565-NB, 9565-A-NB, 9565-P-NB)
. Range: 250 to 15,500 ft/min (1.27 to 78.7 m/s)
. Accuracy: ±1.5% at 2,000 ft/min (10.16 m/s)
. Resolution: 1 ft/min (0.01 m/s)
Duct Size
. Dimensions: 1 to 500 inches in increments of 0.1 in. (2.5 to 1,270 cm in increments of 0.1 cm)
Volumetric Flow Rate
. Range: Actual range is a function of velocity, pressure, duct size, and K factor
Static/Differential Pressure (Models 9565, 9565-NB, 9565-A, 9565-A-NB, 9565-P, 9565-P-NB)
. Range: -15 to +15 in. H2O (-28.0 to +28.0 mm Hg, -3,735 to +3,735 Pa)
. Accuracy: ±1% of reading ±0.005 in. H2O (±0.01 mm Hg, ±1 Pa)
. Resolution: 0.001 in. H2O (0.1 Pa, 0.01 mm Hg)
Barometric Pressure
. Range: 20.36 to 36.648 in. Hg (517.15 to 930.87 mm Hg)
. Accuracy: ±2% of reading
Instrument Temperature Range
. Operating (Electronics): 40 to 113°F (5 to 45°C)
. Storage: -4 to 140°F (-20 to 60°C)
Data Storage Capabilities
. Range: 26,500+ samples and 100 test IDs
Logging Interval
1 second to 1 hour
Time Constant
User selectable
External Meter Dimensions
3.8 in. x 8.3 in. x 2.1 in. (9.7 cm x 21.1 cm x 5.3 cm)
Meter Weight with Batteries
0.8 lbs. (0.36 kg)
Power Requirements
Four AA-size batteries or AC adapter
Models Available
. 9565-AC: Includes ISO 17025 accreditation for temperature, air velocity, humidity and differential pressure.
. 9565-A: Includes articulated probe.
. 9565-A-AC: Includes articulated probe and ISO 17025 accreditation for temperature, air velocity, humidity and differential pressure.
. 9565-P: Measures differential pressure, barometric pressure and has inputs for two K alloy thermocouples.
. 9565-P-AC: Measures differential pressure, barometric pressure and has inputs for two K alloy thermocouples. Includes ISO 17025 accreditation for differential pressure.
. 9565-X: Measures barometric pressure and has inputs for two K alloy thermocouples.
. 9565-NB: This model does not have Bluetooth® capabilities.
. 9565-NB-AC: Includes ISO 17025 accreditation for temperature, air velocity, humidity and differential pressure. This model does not have Bluetooth capabilities.
. 9565-A-NB: Includes articulated probe. This model does not have Bluetooth capabilities.
. 9565-A-NB-AC: Includes articulated probe and ISO 17025 accreditation for temperature, air velocity, humidity and differential pressure. This model does not have Bluetooth capabilities.
. 9565-P-NB: Measures differential pressure, barometric pressure and has inputs for two K alloy thermocouples. This model does not have Bluetooth capabilities.
. 9565-P-NB-AC: Measures differential pressure, barometric pressure and has inputs for two K alloy thermocouples. Includes ISO 17025 accreditation for differential pressure. This model does not have Bluetooth capabilities.
Accessories
Probes:
960: Thermoanemometer Telescopic Straight Probe Velocity and Temperature
962: Thermoanemometer Telescopic Articulating Probe Velocity and Temperature
964: Thermoanemometer Telescopic Straight Probe Velocity, Temperature and Humidity
966: Thermoanemometer Telescopic Articulating Probe Velocity, Temperature and Humidity
995: Rotating Vane 4 in. (100 mm) Probe Velocity
and Temperature
980: IAQ Probe C02, Temperature and Humidity
982: IAQ Probe Model CO, C02, Temperature and Humidity
792: Thermocouple Surface Temperature Probe (Type K)
794: Thermocouple Air Temperature Probe (Type K)
984: Low Concentration (ppb) tVOC and Temperature
985: High Concentration (ppm) tVOC and Temperature
986: Low Concentration (ppb) tVOC, Temperature, CO2, and Humidity
987: High Concentration (ppb) tVOC, Temperature, CO2, and Humidity
Associated services
. First level maintenance and repair work performed by Aerometrik.
. Taking charge of and monitoring the metrology of this equipment with TSI.